# TCA9548A I2C multiplexer: 8 channels, 1.65 to 5.5 V

> An 8-channel I2C switch that fixes address clashes: supply, clock, level translation and the select-a-channel-first rule.

Canonical: https://roboticsengineering.in/components/tca9548a-i2c-multiplexer/ | Published: 2026-11-03 | Updated: 2026-11-03

**The TCA9548A is an 8-channel I2C switch: one upstream SDA/SCL pair fans out to eight downstream pairs, runs from 1.65 to 5.5 V and clocks up to 400 kHz.** Its main job on a robot is to solve address clashes, for example eight identical sensors that all answer at the same address, by putting one on each channel. Figures are from the Texas Instruments TCA9548A datasheet SCPS207H.

## Key specifications

| Channels | 8 |
| --- | --- |
| Supply | 1.65–5.5 V |
| Clock | up to 400 kHz |
| Level translation | 1.8 / 2.5 / 3.3 / 5 V |
| Addresses | 3 pins, up to 8 devices |
| Reset | active-low RESET input |

## What the datasheet promises

| Item | Datasheet value |
| --- | --- |
| Channels | 1-to-8 bidirectional translating switches |
| Supply voltage | 1.65 to 5.5 V |
| Clock frequency | 0 to 400 kHz |
| Level translation | Between 1.8 V, 2.5 V, 3.3 V and 5 V buses |
| Input tolerance | 5 V tolerant inputs |
| Channel selection | Through the I2C bus, any combination of channels |
| Addresses | Three address pins, up to eight devices on one bus |
| Reset | Active-low RESET input; power-on reset deselects all channels |
| Power-up | All channels deselected, no glitch, supports hot insertion |

Because every channel is off after power-up, nothing downstream is visible until you write the control register to select a channel. A common beginner symptom is a scanner that finds only the multiplexer itself: select a channel first, then scan.

## Using it on a robot

- Connect the controller to the upstream SDA and SCL, and each sensor to one SDn/SCn pair.
- Write the channel bit before talking to a sensor, and select one channel at a time unless you want devices to share a bus segment.
- Each downstream segment needs its own pull-up resistors when the breakout does not include them.
- Wire RESET high, or to a controller pin, so you can free a stuck downstream bus without removing power.
- Use the three address pins to run up to eight multiplexers on one bus, which gives many channels.

It pairs well with identical sensors such as several [MPU6050](https://roboticsengineering.in/components/mpu6050-imu/) boards, which only have two selectable addresses. For servo outputs over I2C, see the [PCA9685](https://roboticsengineering.in/components/pca9685-servo-driver/).

## Sources and further reading

- [Texas Instruments TCA9548A datasheet (SCPS207H)](https://www.ti.com/lit/ds/symlink/tca9548a.pdf) — every figure in the table above.

Last reviewed: November 2026. Limits are from the Texas Instruments datasheet; breakout boards vary. No price is quoted because it has not been checked.