Compute minimum protective separation distance (Sp) for laser-scanner Speed & Separation Monitoring (SSM), search Annex A quasi-static & transient force/pressure caps, and run the 2025 cell validation checklist.
ISO/TS 15066 defines Sp = Sh + Sr + Ss + C + Zd + Zr, summing human walking distance during reaction and stopping time, robot travel during controller reaction, robot stopping distance, safety scanner intrusion distance C, and scanner/robot position uncertainties.
The 2025 revision absorbs ISO/TS 15066 power-and-force limiting (PFL) and speed-and-separation monitoring (SSM) directly into the main standard, tightens OT cybersecurity controls, and requires full cell-level validation including end-effector and workpiece geometry.
Compliance applies to the complete robot application, not the bare arm. Sharp grippers, rigid heavy payloads, small contact areas, or clamping pinch points against a fixture can exceed biomechanical pressure limits (N/cm2) even at modest joint torque.
ISO 13855 and ISO/TS 15066 assume vh = 1600 mm/s for walking approach toward the hazard zone when separation is 500 mm or greater (2000 mm/s for short reach below 500 mm).