# FANUC Robot Fault Codes \(SRVO, MOTN, INTP, SYST\): Troubleshooting & Reset

> Diagnose FANUC SRVO-001, SRVO-021, SRVO-050, SRVO-062 BZAL, SRVO-068, MOTN & INTP alarms with Zero Position Mastering steps and payload sizing.

Canonical: https://roboticsengineering.in/fanuc-robot-fault-codes-srvo-motn-troubleshooting/ | Published: 2026-11-20 | Updated: 2026-11-20

FANUC R-30iB / R-30iA · OEM Fault Hub

## FANUC Robot Fault Codes (SRVO, MOTN, INTP, SYST): Troubleshooting & Reset

Search FANUC SRVO, MOTN, INTP, and SYST alarm codes, pulse coder BZAL battery recovery, and Zero Position Mastering steps.

Instant Filter (Code, Alarm Name, or Symptom)

Showing 10 of 10 FANUC OEM fault codes

FANUC · SRVO-001 **Operator Panel E-Stop**

Critical E-Stop

**Root Cause:** Operator panel emergency stop button pressed or broken NC contact on E-stop loop.

**Recovery Steps:** Twist-release E-stop button, verify dual-channel 24V continuity on EES1/EES2 terminals, then press RESET.

**Safety Interlock:** Confirm cell perimeter is clear before resetting safety relay.

FANUC · SRVO-002 **Teach Pendant E-Stop**

Critical E-Stop

**Root Cause:** Teach pendant E-stop switch engaged or damaged pendant cable wiring.

**Recovery Steps:** Release teach pendant E-stop, inspect pendant connector pins, and press RESET on SOP/TP.

**Safety Interlock:** Never bypass pendant deadman or E-stop circuits.

FANUC · SRVO-003 **Deadman Switch Released**

Safety/I-O

**Root Cause:** Teach pendant is enabled in T1/T2 mode while the 3-position deadman switch is released or squeezed too hard.

**Recovery Steps:** Hold the deadman switch lightly at its center position before jogging or pressing RESET.

**Safety Interlock:** In T1 mode speed is limited to 250 mm/s for operator safety.

FANUC · SRVO-021 **SRDY Off (Servo Not Ready)**

Servo/Drive

**Root Cause:** Servo amplifier failed to energize or blown DC link fuse / contactor fault.

**Recovery Steps:** Inspect 3-phase input voltage, servo amp status LEDs, and emergency stop board fuses (F1/F2).

**Safety Interlock:** Wait 5 minutes after power off for DC bus capacitors to discharge.

FANUC · SRVO-023 **Stop Error Excess**

Motion/Collision

**Root Cause:** Axis failed to reach commanded target within servo lag tolerance due to mechanical jam, brake not releasing, or overload.

**Recovery Steps:** Inspect axis for tooling collision, check 90V/24V brake release voltage, and verify payload settings.

**Safety Interlock:** Support heavy vertical axes before mechanically releasing motor brakes.

FANUC · SRVO-050 **Collision Detect Alarm**

Motion/Collision

**Root Cause:** Motor disturbance torque exceeded disturbance threshold from impact or tight cable dress pack.

**Recovery Steps:** Switch to T1, jog carefully away from obstacle, inspect EOAT alignment, and adjust collision guard sensitivity if false trip.

**Safety Interlock:** Verify TCP and fixture zero after any physical impact.

FANUC · SRVO-062 **BZAL (Battery Zero Alarm)**

Servo/Drive

**Root Cause:** Pulse coder backup batteries depleted below 2.6V while controller power was off.

**Recovery Steps:** Replace 4x D-cell alkaline batteries with controller powered ON, reset pulse coder alarm, and perform Zero Position Mastering.

**Safety Interlock:** Always replace encoder batteries while main power is ON to preserve mastering.

FANUC · SRVO-068 **DTERR (Serial Pulse Coder Data Error)**

Servo/Drive

**Root Cause:** Noise or broken differential pair on motor pulsecoder feedback cable inside robot arm harness.

**Recovery Steps:** Inspect M12/Honda feedback connectors, shield grounding, and continuity of SD/REQ pairs in internal dress pack.

**Safety Interlock:** Lock out main disconnect before unplugging servo amplifier connectors.

FANUC · SRVO-105 **Door Open / Fence Open**

Safety/I-O

**Root Cause:** Safety gate interlock (EAS1/EAS2) opened while controller was in AUTO mode.

**Recovery Steps:** Close all safety gates, verify dual-channel interlock switch alignment, reset external safety relay, and press RESET.

**Safety Interlock:** Perform full cell sweep prior to re-arming AUTO.

FANUC · INTP-127 **Power Fail Detected / Program Aborted**

Servo/Drive

**Root Cause:** Brief AC mains sag or uncommanded power loss during motion execution.

**Recovery Steps:** Inspect plant 3-phase supply voltage, UPS/line reactor health, clear fault, and run recovery path.

**Safety Interlock:** Check part grip state before resuming cycle.

### FANUC BZAL Reset & Zero Position Mastering Procedure

1. Keep main controller power ON when replacing the 4x D-cell 6V pulse coder battery pack in the robot base to avoid losing mastering.
2. Press MENU -> SYSTEM -> Master/Cal (if hidden, set system variable $MASTER_ENB = 1).
3. To clear SRVO-062 BZAL / SRVO-038: press F3 RES_PCA -> YES, then cycle controller power.
4. Jog all axes to their physical Zero-Degree witness marks in JOINT mode (T1 <= 250 mm/s) and select ZERO POSITION MASTER -> F4 YES.
5. Execute CALIBRATE -> F4 YES and verify TCP repeatability on a known reference pointer before switching back to AUTO.

`<iframe src="https://roboticsengineering.in/fanuc-robot-fault-codes-srvo-motn-troubleshooting/" width="100%" height="780" style="border:1px solid #d6dfeb;border-radius:12px;" loading="lazy" title="FANUC Robot Fault Codes (SRVO, MOTN, INTP, SYST): Troubleshooting & Reset"></iframe>`

**Grow Your Robotics / Automation Brand Online with Jaadu Digital** Technical SEO, B2B lead generation, and engineering content systems built for robotics integrators and OEMs.

[Explore Jaadu Digital →](https://jaadudigital.com/)

### Frequently Asked Engineering Questions

**How do I clear FANUC SRVO-062 BZAL without losing calibration?**

Replace the 4x D-cell alkaline batteries in the manipulator base with controller power ON, open SYSTEM -> Master/Cal, execute RES_PCA, cycle power, and jog to witness marks if zero reference was already lost.

**What causes FANUC SRVO-050 Collision Detect false trips?**

False SRVO-050 alarms commonly occur when actual EOAT mass or CoG offsets do not match SYSTEM -> Motion Payload Setup, or when a stiff hose dress pack snags during wrist rotation.

**How do I reset FANUC SRVO-001 or SRVO-105 safety fence alarms?**

Verify dual-channel 24V continuity across EES1/EES2 or EAS1/EAS2 on the emergency stop board, close safety gates, reset the external safety relay, and press RESET on the iPendant.

Wrist Kinematics · Static + Dynamic Moment + Inertia J

## Robot Payload, Wrist Torque & Inertia Calculator

PASS — Within Envelope

EOAT / Gripper Mass (kg)

Workpiece Mass (kg)

Load Inertia Approximation

Axial CoG Offset Z from Flange (mm)

Radial CoG Offset X/Y (mm)

Part Half-Span / Radius (mm)

Peak Linear Acceleration (m/s²)

Peak Wrist Angular Accel (rad/s²)

Engineering Safety Factor

Robot Rated Payload (kg)

Rated Wrist Torque (Nm)

Rated Wrist Inertia (kg·m²)

Total Flange Mass

6.60 kg (66%)

Static Wrist Moment

10.28 Nm

Peak Combined Torque (SF)

33.90 Nm

Flange Inertia J

0.219 kg·m²

`<iframe src="https://roboticsengineering.in/robot-payload-inertia-torque-calculator/" width="100%" height="780" style="border:1px solid #d6dfeb;border-radius:12px;" loading="lazy" title="Robot Payload, Wrist Moment & Inertia Calculator"></iframe>`

**Grow Your Robotics / Automation Brand Online with Jaadu Digital** Technical SEO, B2B lead generation, and engineering content systems built for robotics integrators and OEMs.

[Explore Jaadu Digital →](https://jaadudigital.com/)

### Frequently Asked Engineering Questions

**Why can a 10 kg rated robot overload with only a 6 kg gripper and part?**

Catalog payload ratings assume a short CoG offset (often 80–100 mm). Long cantilevered tooling or high linear/angular accelerations exceed the rated wrist torque (Nm) and inertia (kg·m²) before total mass hits 10 kg.

**How is effective mass moment of inertia J calculated at the flange?**

By the parallel-axis theorem: J = I_cm + m \* r², where I_cm is the load inertia about its own center of mass, m is total flange mass, and r is the 3D CoG distance from the wrist axis.

**What safety factor should I use for dynamic robot payload sizing?**

Use 1.25x for steady pick-and-place, 1.4x for high-speed palletizing or E-stop deceleration, and 1.5x+ when handling eccentric castings or vacuum-gripped sheet metal.

**Does entering wrong payload data affect robot accuracy and brake wear?**

Yes. Wrong payload mass or CoG causes overshoot, false collision trips, premature harmonic-drive wear, and longer stopping distances during Category 1 safety stops.

**How do I reduce wrist torque without buying a larger robot?**

Move heavy solenoid valves and vacuum generators off the EOAT onto the upper arm, shorten flange standoffs, and align the heaviest part dimension along the J6 rotation axis.