Series adds voltage, parallel adds capacity, and the C rating sets the current limit. Enter the cell and the layout to get the pack figures.
Use the continuous rating from the cell datasheet, not the peak. Keep margin, and use a proper battery management board.
How it is calculated
Pack voltage = cells in series × cell voltage. Pack capacity = cells in parallel × cell capacity. Energy in Wh = nominal voltage × capacity. Maximum continuous current = capacity in Ah × C rating.
A worked example
A 3S2P pack of 2.5 Ah cells at 3.7 V nominal gives 3 × 3.7 = 11.1 V nominal (12.6 V full), 2 × 2.5 = 5 Ah and 11.1 × 5 = 55.5 Wh. With a 10C rating the limit is 5 × 10 = 50 A.
Common mistakes
- Treating the full-charge voltage as the working voltage.
- Using the peak C rating as the continuous one.
- Mixing old and new cells in one pack.
Related
battery runtime calculator, robot battery guide, wheel speed calculator.
Last reviewed: November 2026. The calculator runs in your browser and sends nothing anywhere. Results are ideal-case figures; add margin before you order parts.
A second worked example
Take a 4S3P pack of 3.0 Ah cells with a nominal voltage of 3.6 V and a full voltage of 4.2 V per cell.
- Nominal voltage = 4 × 3.6 = 14.4 V. Full voltage = 4 × 4.2 = 16.8 V.
- Capacity = 3 × 3.0 = 9 Ah.
- Energy = 14.4 × 9 = 129.6 Wh.
- With a continuous rating of 2C: 9 × 2 = 18 A.
If a robot draws 36 W on average, an ideal runtime is 129.6 ÷ 36 = 3.6 hours. In practice you cannot use all the capacity, so plan for less.
How to read the notation
In 4S3P, S counts cells in series and P counts parallel cells per group, so the pack has 4 × 3 = 12 cells. Cells in series are connected end to end and add voltage. Cells in parallel are tied together and add capacity and current ability.
Assumptions and limits
- Nominal voltage is an average; the real voltage drops as the cell discharges. Check the discharge curve in the cell datasheet and the lowest allowed cell voltage.
- Rated capacity is measured at a particular discharge current. At a higher current the available capacity is often lower.
- The C-rate current is a limit for the cell, not a target. Pack wiring, connectors and the protection board must also handle the current.
- Lithium cells need a battery management system or protection board with balancing for series packs, and a charger made for that chemistry.
Common mistakes
- Putting cells of different capacity or age in one pack.
- Choosing a pack by capacity alone and ignoring the maximum current of the motors at stall.