Live Battery Runtime, C-Rate & Wire Gauge Calculator

Voltage (Full / Nom / Cut)
16.8 / 14.8 / 13.2 V
Pack Energy & Runtime
74.0 Wh · 20.0 min
Max Continuous Output
125 A (Peak Ok)
Min Silicone Wire Gauge
12 AWG (3.31 mm²)

1S–12S Robot Battery Voltage-to-SOC Chart

Series100% Full80%50% Storage20% Alarm0% Load Cutoff
1S
2S
3S
4S
5S
6S
7S
8S
10S
12S

Silicone Wire AWG & Metric mm² Ampacity Table

AWG SizeCross-SectionCopper Dia (mm / in)Continuous10s BurstResistanceTypical Robot Application
22 AWG0.326 mm²0.64 mm (0.025 in)5 A8 A52.9 mΩ/m (16.1 mΩ/ft)Logic / Sensor / Servo Signal
18 AWG0.823 mm²1.02 mm (0.040 in)12 A18 A21.0 mΩ/m (6.4 mΩ/ft)Small Stepper / 1A–8A Sub-Rail
16 AWG1.31 mm²1.29 mm (0.051 in)18 A28 A13.2 mΩ/m (4.0 mΩ/ft)Rover Logic + Light Actuator Bus
14 AWG2.08 mm²1.63 mm (0.064 in)25 A40 A8.28 mΩ/m (2.5 mΩ/ft)XT30 / Medium 15–25A Drive Bus
12 AWG3.31 mm²2.05 mm (0.081 in)35–45 A65 A5.21 mΩ/m (1.6 mΩ/ft)XT60 Main Pack Lead (3S–6S)
10 AWG5.26 mm²2.59 mm (0.102 in)55–65 A95 A3.28 mΩ/m (1.0 mΩ/ft)XT90 Combat / AMR Main Bus
8 AWG8.37 mm²3.26 mm (0.128 in)80–90 A140 A2.06 mΩ/m (0.63 mΩ/ft)AS150 / Heavy 48V AMR Bus
6 AWG13.3 mm²4.12 mm (0.162 in)110–125 A200 A1.30 mΩ/m (0.40 mΩ/ft)Forklift / High-Power Inverter Bus
4 AWG21.2 mm²5.19 mm (0.204 in)150–170 A260 A0.81 mΩ/m (0.25 mΩ/ft)Industrial AGV Main Battery Feed
Grow Your Robotics / Automation Brand Online with Jaadu Digital Technical SEO, B2B lead generation, and engineering content systems built for robotics integrators and OEMs.
Explore Jaadu Digital →

Frequently Asked Engineering Questions

What is the safe minimum discharge voltage for a LiPo robot battery under load?

Avoid discharging LiPo or Li-Ion cells below 3.3V per cell under load (3.5V resting) to prevent irreversible capacity loss; LiFePO4 packs can safely run down to 2.8V per cell under load.

How do I calculate continuous amps from mAh and C-rating?

Multiply capacity in Ah (mAh / 1000) by the continuous C-rating. For example, a 5000 mAh (5 Ah) 25C pack supports 5 x 25 = 125 A continuous, though keeping load under 70% improves cycle life.

What silicone wire AWG should I use for 30A, 60A, or 100A robot power buses?

Use 12 AWG (3.3 mm²) for up to 35-45A continuous, 10 AWG (5.3 mm²) for 55-65A, and 8 AWG (8.4 mm²) or 6 AWG (13.3 mm²) for 80-120A main motor buses with XT60/XT90/Anderson connectors.

DC Silicone Harness & Voltage Drop Check: A 6S LiPo pack sags fast enough under motor stall without losing another 1.5 V in undersized XT60 or Anderson leads. Before crimping battery leads, convert AWG to mm² and verify DC loop voltage drop at peak discharge amps on the EngiTech AWG to mm² Cable Size & Voltage Drop Calculator.